Back
Caratteristiche funzionali
Process temperature
  • Vedere il capitolo “Condizioni di funzionamento”.
Pt100 accuracy class (EN 60751)
  • Standard response tip
  • B (± 0,3 °C a 0 °C)
  • ± (0.3 + 0.005 × t)°C
  • A (± 0,15 °C a 0 °C)
  • ± (0.15 + 0.002 × t)°C
  • 1/3 B (± 0.1 °C at 0 °C)
  • ± 1/3 × (0.3 + 0.005 × t)°C
  • 1/6 B (± 0,05 °C a 0 °C)
  • ± 1/6 × (0.3 + 0.005 × t)°C
Max. output error
  • ≤ 0,06 % FSR @ 25 °C
  • Including input accuracy, output accuracy and repeatability
Temperature drift (by ambient)
  • < 0,025 K/K + 0,01 % FSR/K
Thermal response time, T90
  • RTD element and transmitter combined
  • < 8,9 s , Ø6 mm
Raccordo di processo
Sensor length
  • ≤ 3000 mm
Sensor tube material
  • AISI 316L (1.4404)
Surface roughness wetted parts
  • Ra ≤ 0.8 µm
Condizioni ambientali
Classe di protezione (EN 60529)
  • Connettore DIN EN 175301-803 A (DIN 43650 A), a 4 poli:
  • IP65
  • Connettore M12-A, a 4 poli:
  • IP68 , con cavo appropriato (336 h @ 10 mH2O)
  • IP69K , con cavo appropriato
Humidity
  • ≤ 100 % RH , condensazione
Vibration (sinusoidal) (EN 60068-2-6)
  • 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
  • GL, test 2
Segnale di uscita
Output type
  • PNP
  • NPN
  • Digital (push-pull)
  • 4 … 20 mA, 2-wire
  • 20 … 4 mA, 2-wire
Switching logic
  • Active high
  • Active low
Voltage drop
  • PNP: (+Vs – 1,2 V) ± 0.5 V, Rload ≥ 10 kΩ
  • NPN: (-Vs + 1,5 V) ± 0.5 V, Rload ≥ 10 kΩ
Current rating
  • 100 mA , max.
Off leak current
  • < 100 μA
Protezione contro i corto circuiti
Conformità e omologazioni
Immunità elettromagnetica
  • EN 61326-1
Safety
  • elenco cULus, E527512